NA-MAAB — No recommendations
JMAAB — a
All
Block parameter Sample time shall be set to
-1
(inherited).
Inport block
Outport block
Atomic subsystem
Blocks with state variables, such as Unit Delay and Memory
Signal conversion blocks, such as Data Type Conversion and Rate Transition
Blocks that do not have external inputs, such as Constant
Stateflow® charts
Not Applicable
Sub ID a:
Discrepancies can occur in the processing of the model because of different simulation times.
Maintainability of the model deteriorates when a specific sample time is set for each block individually.
Model Advisor check: Check for sample time setting (Simulink Check)
R2020a
JMAAB guideline jc_0641, which is available in Control Algorithm Modeling Guidelines Using MATLAB, Simulink, and Stateflow on the MathWorks® website.
Construct and Run a Stateflow Chart (Stateflow)