NA-MAAB — a
JMAAB — a
All
Saturation and Saturation Dynamic blocks shall be used to limit physical quantity.
Type conversion shall not be used. Block parameters Upper limit and Lower limit shall not be set.
Not Applicable
The Saturation Dynamic block is limiting physical quality.
The Saturation Dynamic block is not being used to limit physical quantity. Type conversion is being used. The upper and lower limits for the data type maximum and minimum values are set.
Sub ID a:
Consistent use of Saturation blocks improve maintainability of the model.
Model Advisor check: Check usage of the Saturation blocks (Simulink Check)
R2020a
JMAAB guideline jc_0628, which is available in Control Algorithm Modeling Guidelines Using MATLAB, Simulink, and Stateflow on the MathWorks® website.