NA-MAAB — a
JMAAB — a, b
All
Discrete-Time Integrator block parameters Upper saturation limit and Lower saturation limit shall be defined.
Not Applicable
When Discrete-Time Integrator block
parameters Upper saturation limit and Lower
saturation limit are defined as
Simulink.Parameter
, parameter Data
type shall be set to auto
.
Not Applicable
Sub ID a:
Avoids block output overflow and prevents other computation blocks that use the output of this block from producing unexpected results.
Sub ID b:
Simulation errors occur when Data type is set
to a value other than auto
, single
, or
double
.
Model Advisor check: Check usage of Discrete-Time Integrator block (Simulink Check)
R2020a
JMAAB guideline jc_0627, which is available in Control Algorithm Modeling Guidelines Using MATLAB, Simulink, and Stateflow on the MathWorks® website.