NA-MAAB — No recommendations
JMAAB — a1/a2/a3/a4, b1/b2/b3/b4
All
The name of the conditional input block at the destination shall include the name of the block at the origin of the trigger signal
Not Applicable
The name of the conditional subsystem at the destination shall include the name of the block at the origin of the trigger signal.
Not Applicable
The name of the conditional input block at the destination shall include the name of the trigger signal.
Not Applicable
The name of the conditional subsystem at the destination shall include the name of the trigger signal.
Not Applicable
The name of the Stateflow® block event at the destination shall include the name of the block at the origin of the trigger signal.
Not Applicable
The name of Stateflow Chart (Stateflow) at the destination shall include the name of the block at the origin of the trigger signal.
Not Applicable
The name of the Stateflow block event at the destination shall include the name of the trigger signal.
Not Applicable
The name of the trigger signal and the Stateflow Chart (Stateflow) name at the destination must include the same name. The name of the Chart block at the destination shall include the name of the trigger signal.
Not Applicable
Sub ID a1, a2, a3, a4, b1, b2, b3, b4:
Reduces connection mistakes.
Increases understanding of the relationship between the origin of the trigger signal and the destination.
Model Advisor check: Check trigger signal names (Simulink Check)
R2020a
Sub ID a1, a2, a3, a4, see MISRA AC SLSF 026C
JMAAB guideline jc_0281, which is available in Control Algorithm Modeling Guidelines Using MATLAB, Simulink, and Stateflow on the MathWorks® website.
Use Events to Execute Charts (Stateflow)