Main Content

Repair bus selections

Diagnostic action to take when upstream bus hierarchy changes break selections

Model Configuration Pane: Diagnostics / Connectivity

Description

The Repair bus selections configuration parameter determines the diagnostic action to take when changes to the upstream bus hierarchy break selections for Bus Selector and Bus Assignment blocks. By default, the software repairs the selections.

Settings

Warn and repair (default) | Error without repair
Warn and repair

The software displays a warning and updates the Bus Selector and Bus Assignment block parameter values to reflect upstream bus hierarchy changes.

Error without repair

The software displays an error and terminates the simulation. The error message indicates the block parameter values that you must update for the Bus Selector and Bus Assignment blocks to reflect upstream bus hierarchy changes.

Recommended Settings

ApplicationSetting
DebuggingNo impact
TraceabilityNo impact
EfficiencyNo impact
Safety precautionWarn and repair

Programmatic Use

Parameter: BusNameAdapt
Values: 'WarnAndRepair' | 'ErrorWithoutRepair'
Default: 'WarnAndRepair'

Version History