Enforce sample times specified by Signal Specification blocks
Description
Select the diagnostic action to take if the sample time of the source port of a signal specified by a Signal Specification block differs from the signal's destination port.
Category: Diagnostics
Settings
Default:
warning
none
Simulink® software takes no action.
warning
Simulink software displays a warning.
error
Simulink software terminates the simulation and displays an error message.
Note
The setting of this diagnostic is ignored when the Default parameter
behavior parameter in the Code Generation > Optimization pane of the model Configuration Parameters is set to
Tunable
.
Tips
The Signal Specification block allows you to specify the attributes of the signal connected to its input and output ports. If the specified attributes conflict with the attributes specified by the blocks connected to its ports, Simulink software displays an error when it compiles the model, for example, at the beginning of a simulation. If no conflict exists, Simulink software eliminates the Signal Specification block from the compiled model.
You can use the Signal Specification block to ensure that the actual attributes of a signal meet desired attributes, or to ensure correct propagation of signal attributes throughout a model.
Command-Line Information
Parameter:
SigSpecEnsureSampleTimeMsg |
Value:
'none' | 'warning' |
'error' |
Default:
'warning' |
Recommended Settings
Application | Setting |
---|---|
Debugging | No impact |
Traceability | No impact |
Efficiency | No impact |
Safety precaution | error |