Main Content

Ideal Torque Source

Ideal source of mechanical energy that generates torque proportional to the input signal

  • Ideal Torque Source block

Libraries:
Simscape / Foundation Library / Mechanical / Mechanical Sources

Description

The Ideal Torque Source block represents an ideal source of mechanical energy that generates torque proportional to the input physical signal. The source is ideal in a sense that it is assumed to be powerful enough to maintain specified torque regardless of the angular velocity at source terminals.

Connections R and C are mechanical rotational conserving ports. Port S is a physical signal port, through which the control signal that drives the source is applied. You can use the entire variety of Simulink® signal sources to generate the desired torque variation profile. Positive signal at port S generates torque acting from C to R. The torque generated by the source is directly proportional to the signal at the control port S.

The block positive direction is from port C to port R. This means that the torque is positive if it acts in the direction from C to R. The relative velocity is determined as ω = ωCωR, where ωR, ωC are the absolute angular velocities at ports R and C, respectively, and it is negative if velocity at port R is greater than that at port C. The power generated by the source is negative if the source delivers energy to port R.

Ports

Input

expand all

Physical signal input port, through which the control signal that drives the source is applied.

Conserving

expand all

Mechanical rotational conserving port associated with the source moving part (rod).

Mechanical rotational conserving port associated with the source reference point (case).

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Version History