%<BaseSampleTime> variable not available in simulink model-tlc file?
1 Ansicht (letzte 30 Tage)
Ältere Kommentare anzeigen
Sietse
am 9 Jun. 2015
Beantwortet: Drew Davis
am 10 Jun. 2015
I am trying to create a simulink block that should depend on the base-sample-rate of the model. I tried to put the following in the model-block-tlc file:
%if %<BaseSampleTime> > 0.003
adc1_sum = 0;
for (int i=0; i<8; i++ ) {
adc1_sum += Get_ADC_Value(11);
}
%else
adc1_sum= Get_ADC_Value(11)*8;
%endif
But I get: Undefined identifier BaseSampleTime
Is there a way to determine this value in the models tlc-file? (apart from creating a variable when this value is in scope?)
Thanks in advance, Sietse
0 Kommentare
Akzeptierte Antwort
Drew Davis
am 10 Jun. 2015
I do not know of any TLC function to get the base sample time of the model. There is however a list of TLC sample time functions that you may find useful. For instance, the function 'LibBlockSampleTime(block)' allows you to access the sample time of the block.
0 Kommentare