Main Content

Shunt L

Model shunt inductor

  • Shunt L block

Libraries:
RF Blockset / Equivalent Baseband / Series / Shunt RLC

Description

The Shunt L block models the shunt inductor described in the block dialog box, in terms of its frequency-dependent S-parameters

The shunt L object is a two-port network, as shown in the following circuit diagram.

Two-port shunt L network

Parameters

expand all

Main

Scalar value for the inductance. The value must be non-negative.

Visualization

Frequency data source, specified as User-specified.

Frequency data range, specified as a vector in hertz.

Reference impedance, specified as a nonnegative scalar in ohms.

Type of data plot to visualize using the given data, specified as one of the following:

  • X-Y plane — Generate a Cartesian plot of the data versus frequency. To create linear, semilog, or log-log plots, set the Y-axis scale and X-axis scale accordingly.

  • Composite data — Plot the composite data. For more information, see Create Plots Using Equivalent Baseband Library Blocks.

  • Polar plane — Generate a polar plot of the data. The block plots only the range of data corresponding to the specified frequencies.

  • Z smith chart, Y smith chart, and ZY smith chart — Generate a Smith® chart. The block plots only the range of data corresponding to the specified frequencies.

Type of parameters to plot based on the Plot type you set, specified as one of the following.

Plot typeY parameter1
X-Y planeS11, S12, S21, S22, GroupDelay, OIP3, NF, NFactor, and NTemp.
Composite dataNo Y parameter1 to set.
Polar planeS11, S12, S21, and S22
Z Smith chartS11 and S22.
Y Smith chartS11 and S22.
ZY smith chartS11 and S22.

Type of parameters to plot based on the Plot type you set, specified as one of the following.

Plot typeY parameter2
X-Y planeS11, S12, S21, S22, GroupDelay, OIP3, NF, NFactor, and NTemp.
Composite dataNo Y parameter2 to set.
Polar planeS11, S12, S21, and S22
Z Smith chartS11 and S22.
Y Smith chartS11 and S22.
ZY smith chartS11 and S22.

Plot format, specified as one of the following.

Y parameter1Y format1
S11, S12, S21, and S22.Magnitude (decibels), Magnitude (linear), Angle(degrees), Angle(radians), Real, and Imaginary.
GroupDelayns, us, ms, s, and ps.
OIP3dB, dBm, W, and mW.
NFMagnitude (decibels)
NFactorNone
NTempKelvin

Dependencies

To enable Y format1, set Plot type to X-Y plane.

Plot format, specified as one of the following.

Y parameter2Y format2
S11, S12, S21, and S22.Magnitude (decibels), Magnitude (linear), Angle(degrees), Angle(radians), Real, and Imaginary.
GroupDelayns, us, ms, s, and ps.
OIP3dB, dBm, W, and mW.
NFMagnitude (decibels)
NFactorNone
NTempKelvin

Dependencies

To enable Y format2, set Plot type to X-Y plane.

Frequency plot, specified as Freq.

Frequency plot format, specified as one of the following.

AutoHzkHzMHz
GHzTHz  

Y-axis scale, specified as Linear or Log.

Dependencies

To enable this parameter, set Plot type to X-Y plane.

X-axis scale, specified as Linear or Log.

Dependencies

To enable this parameter, set Plot type to X-Y plane.

Plot the specified data using the plot button.

Version History

Introduced before R2006a