Documentation

Destination

Indicates trigger destination terminal

Description

When working with the session-based interface, the Destination property indicates the device and terminal to which you connect a trigger.

Example

Examine a Trigger Connection Destination

Create a session with a trigger connection and examine the connection properties.

Create a session and add 2 analog input channels form different devices.

s = daq.createSession('ni');
addAnalogInputChannel(s,'Dev1', 0, 'voltage');
addAnalogInputChannel(s,'Dev2', 0, 'voltage');

Add a trigger connection and examine the connection properties.

addTriggerConnection(s,'Dev1/PFI4','Dev2/PFI0','StartTrigger')
ans =


Start Trigger is provided by 'Dev1' at 'PFI4' and will be received by 'Dev2' at terminal 'PFI0'.

     TriggerType: 'Digital'
TriggerCondition: RisingEdge
          Source: 'Dev1/PFI4'
     Destination: 'Dev2/PFI0'
            Type: StartTrigger